Tokyo District Court, Reiwa 5 (Wa) 70738 [Wine cellar] <Presiding Judge Takahashi>

10月2日
読了時間: 1分

更新日:5 日前

Article information

Article type: Case note

Category: Patents

Issues: Claim interpretation

First published on this website: 2026-10-03

Display and classification checked: 2026-10-03

Tokyo District Court, Reiwa 5 (Wa) 70738 [Wine cellar] <Presiding Judge Takahashi>

Element E3: “Restarting the compressor when the temperature around the cooler, after stopping the heating heater, reaches a ‘third temperature (second temperature < third temperature).’”

⇒ In the defendant's product, the heater-stop temperature (P11) and the compressor-restart temperature (P6) were set to the same temperature.

The defendant's product has a “compressor protection function (delay timer),” so restart may take time even with identical temperature settings. However, experiments showed cases in which the temperature at restart was lower than at heater stoppage. It could not be found that control consistently used a “third temperature higher than the second temperature.”

⇒ Claim element not satisfied.

Update and correction history

Substantive corrections, additions, classification, related-article and display changes are recorded separately from the website's first-publication date.

2026-10-03: First publication from the LinkedIn original; article information, issue tags, language navigation and consultation guidance were added.

2026-10-13: aligned the canonical and search-index URLs with the published URL. The original article text was not changed.

 
 
 